E100
Drive Set Up

The drive operating mode and motor
selection are incompatible.

Change the operating mode and/or the motor
selection, and reset the drive.

E101
Motor Power Cable Open

Motor cable open

Verify power connection between motor and drive.

E102
Motor Instantaneous
Current Overload

Motion profile requires a peak current for
an excessive time interval

• Verify motor wiring.

• Adjust accel/decel time.

• Confirm motor selection.

Defective current feedback sensing

Verify phase currents.

E103
Motor Mismatch

Dynamic braking current of the selected
motor exceeds twice the drive peak
current rating

Install a different motor.

E104
Continuous Power
Overload

Motion application requires average drive
power in excess of rated capability

• Reduce acceleration rates.

• Reduce duty cycle (ON/OFF) of commanded

motion.

• Increase time permitted for motion.

• Use larger drive and motor.

• Check tuning.

E105
Encoder Type Mismatch

Motor encoder signals do not match drive
configuration

Verify motor selection.

Defective encoder

Replace motor.

E106
Encoder Communication
Error

Wiring between drive and encoder is
faulty or disconnected, or EMI (noise)
disrupts encoder signals.

• Verify encoder wiring.

• Contact A-B.

E107
Special Communication
Error

Communications error between host and
drive (noise)

• Verify serial cable.

• Check for noise on serial interface.

E108
Position Command
Frequency Error

Input frequency limit exceeded

• Verify hardware type selected in the drive

matches the physical hardware.

• Change from open collector to line drive.

• Reduce the speed command.

• Apply gearing.

Error Display

Description

Possible Cause(s)

Action/Solution

Code