beautypg.com

Digital outputs, Fault outputs, Analog outputs – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 141: Encoder outputs

background image

Publication 2092-UM001D-EN-P — July 2005

Specifications and Dimensions

A-7

Digital Outputs

Fault Outputs

Analog Outputs

Encoder Outputs

Quantity

3 general purpose, opto-isolated

Type

Differential (both collector and emitter available for connection)

Output Current

20 mA, maximum

Output Voltage

21.6–26.4 Volts

Propagation Delay

50

µs

Firmware Scan delay

2 ms

Assignable Functions

Absolute Position Valid, Brake, Current Limited, Ready, Up to
Speed, Velocity Limited, Warning, Within Near Window, Within
Position Window, Within Speed Window

Quantity

1 fault output and three binary fault code outputs

Type (Fault Output)

Differential (both collector and emitter available for connection)

Type (Fault Code Outputs)

Single-ended, open collector

Output Current

20 mA, maximum

Output Voltage

21.6–26.4 Volts

Propagation Delay

50

µs

Firmware Scan delay

2 ms

Quantity

2 general purpose, voltage source

Type

PWM, 8-bit

Response

4 ms, typical

Output Voltage

-10 to +10 Volts

Output Current

10 mA, maximum

Signals

AM+/-, BM+/-, IM+/-, Z-PULSE+/-

Type

Differential, TTL logic

Frequency

2.5 MHz, maximum

Output Current

20 mA, maximum