beautypg.com

Tl-series motor connections – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 152

background image

Publication 2092-UM001D-EN-P — July 2005

B-8

Interconnect and Cable Diagrams

TL-Series Motor
Connections

Figure B.7 shows the recommended feedback wiring for the TL-Series motors
to the Ultra1500.

Figure B.7
Ultra1500 and TL-Series Motor Feedback Wiring Diagram

ULTRA1500

EPWR

ECOM

SD+

NOTES:

1.

IF MULTI-TURN ABSOLUTE FEEDBACK IS NOT NEEDED IN THE APPLICATION, THE BATTERY CONNECTIONS TO PINS 18 AND 19 OF CN2 ARE
NOT NECESSARY.

MOTOR

FEEDBACK

CONNECTOR

1

SD-

BAT+

BAT-

20

1

10

13

18

19

CN2

EPWR

ECOM

SD+

SD-

BAT+

BAT-

SHIELD

SHIELD