beautypg.com

Group 3 parameters, Pr-3.00 follower configuration – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 186

background image

Publication 2092-UM001D-EN-P — July 2005

D-22

Ultra1500 Operator Interface

Group 3 Parameters

Group 3 Parameters provide position control settings.

Pr-3.00 Follower Configuration

Data Size:

4 digits

Digit 0:

Command Type

Range:

Value

Description

0x0

CW + CCW, Positive logic

0x1

CW + CCW, Negative logic

0x2

Pulse Line + Sign, Positive Logic

0x3

Pulse Line + Sign, Negative Logic

0x4

A Phase + B Phase, Positive Logic

0x5

A Phase + B Phase, double input
multiplication, Positive Logic

0x6

A Phase + B Phase, quadruple input
multiplication, Positive Logic

Default:

0x0

Note:

For values 0x4, 0x5, and 0x6, Motor Counts = :

Master Lines * MULT * [(4 * Pr-3.01)/Pr-3.02]

Where the multiplier (MULT) is 1, 2, and 4 for values 0x4, 0x5,
and 0x6 respectively.

Applicable Operating Mode:

Follower

Digit 1:

Controller Output Type

Range:

Value

Description

0

Line Drive

1

Open Collector

Default:

0

Applicable Operating Mode:

Follower

Digit 2:

Encoder Output Forward Direction

Range:

Value

Description

0

During Forward Rotation, Encoder
Output Phase A have a lead of 90× over
Phase B.

1

During Forward Rotation, Encoder
Output Phase B have a lead of 90× over
Phase A.

Default:

0

Applicable Operating Mode:

All

Digit 3:

Reserved