D-30

Ultra1500 Operator Interface

Pr-6.05 Reserved

Pr-6.06 Fault Detail Setup: Sample Period

Pr-6.07 Fault Detail Setup: Channel A

Pr-6.08 Fault Detail Setup: Channel B

Pr-6.09 Fault Detail Setup: Channel C

Default:

0

Applicable Operating Mode:

Follower, Analog Velocity, Preset Velocity

Ultraware Link:

Main Velocity Regulator Gains: D

This parameter is Reserved.

Description:

The time, in 0.2 msec increments, between signal samples.
50 samples constitute a fault trace.

Range:

1 to 99

Default:

5

Units:

0.2 msec

Ultraware Link:

Fault Detail Setup: Sample Period

Description:

Selects the drive signal to assign to a Channel A.

Range:

See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.

Default:

0x00

Ultraware Link:

Fault Detail Setup: Channel A

Description:

Selects the drive signal to assign to Channel B.

Range:

See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.

Default:

0x03

Ultraware Link:

Fault Detail Setup: Channel B

Description:

Selects the drive signal to assign to Channel C.

Range:

See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.

Default:

0x0B

Ultraware Link:

Fault Detail Setup: Channel C