Publication 2092-UM001D-EN-P — July 2005

Ultra1500 Operator Interface

D-31

Pr-6.10 Fault Detail Setup: Channel D

Pr-6.11 Alternate Gain: VReg P Gain

Pr-6.12 Alternate Gain: VReg Integrator Time

Pr-6.13 Alternate Gain: PReg Kp Gain

Pr-6.14 Alternate Gain: IReg Low Pass Bandwidth

Description:

Selects the drive signal to assign to Channel D.

Range:

See Monitor Variable Numbers (except 0x0F) beginning on
page D-6.

Default:

0x10

Ultraware Link:

Fault Detail Setup: Channel D

Description:

This command allows you to set an Alternate Velocity
Regulator P Gain for use in system tuning.

Range:

0 to 1000

Default:

60

Applicable Operating Mode:

Follower, Analog Velocity, Preset Velocity

Ultraware Link:

Alternate Gain Values: VReg P Gain

Description:

This command allows you to set an Alternate Velocity
Regulator Integrator Time for use in system tuning.

Range:

0 to 60000

Default:

26

Applicable Operating Mode:

Follower, Analog Velocity, Preset Velocity

Ultraware Link:

Alternate Gain Values: VReg Integrator Time

Description:

This command allows you to set an Alternate Position
Regulator Kp Gain for use in tuning.

Range:

0 to 700

Default:

20

Units:

Hz

Applicable Operating Mode:

Follower

Ultraware Link:

Alternate Gain Values: PReg Kp Gain

Description:

This command allows you to set an Alternate Low Pass
Bandwidth for use in tuning.

Range:

0 to 10000

Default:

300

Units:

Hz

Applicable Operating Mode:

All

Ultraware Link:

Alternate Gain Values: IReg Low Pass Bandwidth