Parameter groupings, Group 0 parameters – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual
Page 173

Publication 2092-UM001D-EN-P — July 2005
Ultra1500 Operator Interface
D-9
3. Press the ENTER key to display the current value of the parameter.
4. Modify the current value of the parameter with the directional keys, and
save the modified value in memory by pressing the SET key.
5. Press the ENTER key a second time to return to the Set Parameter
display, where you can modify parameter settings.
For example: Enter the Set Parameter mode by pressing the MODE key
(The text message Pr-x.xx indicates the Set Parameter mode is active).
Select a parameter and navigate through the parameter using the
navigational keys (the active digit flashes). Press the ENTER key to display
the current value of the parameter. Modify the parameter setting by using
the LEFT and RIGHT key to move between digits, and the UP or
DOWN key to increment or decrement the flashing parameter value.
Press and hold the SET key to save the new parameter setting (the display
momentarily blanks to indicate the setting is saved). Lastly press ENTER
to return to the Set Parameter display.
Parameter Groupings
This section defines the parameters controlling drive operation. Parameters are
grouped by the category they reside in.
Group 0 Parameters
Group 0 Parameters provide basic drive system and I/O settings.
Pr-0.00 Operation Modes
Range:
Value
Normal Operating
Mode
Override Operating
Mode
1
Follower
Follower
2
Analog Velocity Input
Analog Velocity Input
3
Analog Current Input
Analog Current Input
4
Analog Velocity Input
Follower
5
Analog Current Input
Follower
6
Analog Current Input
Analog Velocity Input
7
Preset Velocity
Preset Velocity
8
Preset Velocity
Follower
9
Preset Velocity
Analog Velocity Input
10
Preset Velocity
Analog Current Input
11
Dual Current Control
Dual Current Control
Default:
2
Ultraware Link:
Main/Override