Parameter groupings, Group 0 parameters – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 173

background image

Publication 2092-UM001D-EN-P — July 2005

Ultra1500 Operator Interface

D-9

3. Press the ENTER key to display the current value of the parameter.

4. Modify the current value of the parameter with the directional keys, and

save the modified value in memory by pressing the SET key.

5. Press the ENTER key a second time to return to the Set Parameter

display, where you can modify parameter settings.

For example: Enter the Set Parameter mode by pressing the MODE key
(The text message Pr-x.xx indicates the Set Parameter mode is active).
Select a parameter and navigate through the parameter using the
navigational keys (the active digit flashes). Press the ENTER key to display
the current value of the parameter. Modify the parameter setting by using
the LEFT and RIGHT key to move between digits, and the UP or
DOWN key to increment or decrement the flashing parameter value.
Press and hold the SET key to save the new parameter setting (the display
momentarily blanks to indicate the setting is saved). Lastly press ENTER
to return to the Set Parameter display.

Parameter Groupings

This section defines the parameters controlling drive operation. Parameters are
grouped by the category they reside in.

Group 0 Parameters

Group 0 Parameters provide basic drive system and I/O settings.

Pr-0.00 Operation Modes

Range:

Value

Normal Operating
Mode

Override Operating
Mode

1

Follower

Follower

2

Analog Velocity Input

Analog Velocity Input

3

Analog Current Input

Analog Current Input

4

Analog Velocity Input

Follower

5

Analog Current Input

Follower

6

Analog Current Input

Analog Velocity Input

7

Preset Velocity

Preset Velocity

8

Preset Velocity

Follower

9

Preset Velocity

Analog Velocity Input

10

Preset Velocity

Analog Current Input

11

Dual Current Control

Dual Current Control

Default:

2

Ultraware Link:

Main/Override