beautypg.com

Analog current mode, Analog current mode -44, Figure 5.25 analog current mode block diagram – Rockwell Automation 2092-DAx Ultra1500 User Manual User Manual

Page 124

background image

Publication 2092-UM001D-EN-P — July 2005

5-44

Ultra1500 Application Examples

Analog Current Mode

Figure 5.25 shows the block diagram for the analog current mode of the
Ultra1500:

Figure 5.25
Analog Current Mode Block Diagram

The current command limit is set to the minimum of the following:

• Positive / Negative Internal Current Limit,
• Positive / Negative External Current Limit,
• Stopping Current (if active), and
• Drive Peak / Motor Peak Current Rating.

Block/Switch definitions shown in Figure 5.25 refer to the Ultraware parameter names where applicable.

+

+

A nalog Cu rrent

Command (Volts)

K

c

Analog Current

Command

Offset (V olts)

2

Block/Switch Definitions:

1

Mode Configuration : Analog : Current Command Offset

2

Mode Configuration : Analog : Current Scale

3

Main Drive Window : Command Polarity

4

Main Drive Window : Current Limits; Main Drive Window : Stopping Functions : Maximum Stopping Current

5

Tuning Window : M ain Current Regulator Gains : Low Pass Filter Bandwidth

6

Tuning Window : M ain Current Regulator Gains : Resonant Frequency Suppression

3

1

-1

4

Curren t

Comma nd to

Curren t

Reg ulator

5

6

Curren t

Cmd
Limit

Current

Cmd

Low Pass

Filter

Curren t

Cmd

Notch Filter

1