If you are
performing
this function:
Complete the following step(s) to:
Perform a Jog (00) function:
1. Press MODE to select the JoG-On display
Note: MODE toggles between JoG-On and JoG-OFF.
2. Press the UP key to jog in the forward direction,
or the DOWN key to jog in the reverse direction.
3. Press MODE to select JoG-OFF.
4. Press the ENTER key to return to the Function Mode
display.
Manually Adjust Velocity Input Offset (05) function, or
Manually Adjust Current Input Offset (06) function:
1. Press MODE to display the default (0.0) value.
2. Press the UP or DOWN to increase or decrease the
offset value by one unit each time the key is pressed.
The default display is 0.0, but a value is set and stored
when the drive is commissioned. The commissioned
value increments when UP is pressed, or decrements
when DOWN is pressed [i.e., The total UP entries are
added to (DOWN entries are subtracted from) the
commissioned value.]
Note: The Velocity Input Offset (05) is stored in Pr
6.00, Current Input Offset in Pr 6.01, or in the
Analog window of Ultraware.
3. Press the SET key to execute the function. An
incrementing border indicates the function is
executing. The text message -donE- displays upon
completion.
4. Press the ENTER key to return to the Function Mode
display.
Perform the other non-reserved function(s).
1. Press the SET key to execute the function. An
incrementing border indicates the function is
executing. The text message -donE- displays upon
completion.
2. Press the ENTER key to return to the Function Mode
display.