beautypg.com

Frame relay port parameters, Frame relay port parameters -14, Table 7-3 – Cabletron Systems 1800 User Manual

Page 82: Table 7-3 frame relay port parameters

background image

7-14

SmartSwitch 1800 4. 0 User G uide, Rev 01

Frame Relay Port Parameters

1 If set to

Y

, no backup DLCIs on this port will be used (even if the port is enabled via

on-line port enable).

2 If one physical frame relay port will connect to several remote sites, be sure the line

speed is adequately higher that the speeds configured on the remote sites.

3 If this port will connect to a frame relay network, set

Logi cal DCE

to

N

. Also note that

one end of a frame relay backup connection must be configured as logical DCE.

4 Not applicable to CSU/DSU ports.
5 This parameter is relevant only if

Physical Port I nterface

is something other than

RS-

232

and

G enerate Clock

is

Y

.

6 Applicable only to CSU/DSU ports.
7 These parameters are relevant only if

Link Layer Management

is

LMI

or

ANNEXD

and

Logical DCE

is

N

.

8

N3

should be greater than or equal to

N2

.

9 If

Link Layer Management

is

none

, this parameter is irrelevant. (If

Link Layer Man-

agement

is changed to none from some other value, the default for

N2

will be left as it

was before the change.)

10

T2

should be greater than or equal to

T1

.

11 This parameter is relevant only if

Logical DCE

is

Y

.

Table 7-3 Frame Relay Port Parameters

Parameter

Valid Values

Default Value

Port Type

Fram e Rel ay

not valid here

Physical Port Interface

see explanation

see explanation

Blocked Port Flag

Y/ N

1

N

Line Speed

(bits per sec)

see explanation

9600

2

Maximum Bytes per Frame

16–4096

1600

Logical DCE

Y/ N

3

Y

Generate Clock

4

Y/ N

Y

Rcv Clock (TT) from DTE

4,5

Y/ N

N

CSU/DSU O perating Mode

6

Normal /LDM

Norm al

RTS Control

6

Constant/External

Constant

Link Layer Management

None, LMI, ANNEXD

None

N1 Polling Count

7

1–6

6

N2 Error Threshold

7

1–10

8

2

if

LMI

9

3

if

Annex D

9

N3 Monitored Events Count

7

1–10

8

4

T1 Link I ntegr ity Timer

(sec)

7

5–30

10

10

T2 Polli ng Veri fi cation Tim er

(sec)

11

5–30

10

15

Enable Outgoing Rate Control

Y/ N

N

Enable Bandwidth Al locati on

Y/ N

N

For Backup Use Onl y?

Y/ N

N

Automatic DCE

Y/ N

N