Syst em Events
22-5
182.
Configured for normal sequence numbering, received SABME
Severity:
4
Meaning:
The Port record is configured for a maximum frame sequence
number (Outstanding Frames) of 7 or fewer, but a command was
received setting the mode to allow up to 127.
Action:
None.
197.
Received FRMR, WXYZ="n", control field="n", V(s)="n", V(r)="n", CMD/RSP="n"
Severity:
2
Meaning:
The RLP HDLC frame processor task received a frame reject
(FRMR) response to a previously transmitted frame.
Action:
The system recovers automatically from this error; however, if the
message is repeated, it may mean that you have a bad communica-
tions line.
198.
SABM/DISC with wrong link address
Severity:
4
Meaning:
The HDLC frame processor task for the port has received an
improperly addressed frame from the subscriber. This situation
usually occurs when the port and subscriber devices are both con-
figured as logical DCEs or logical DTEs.
Action:
Modify the Port record so that one end of the connection is a logical
DCE and the other is a logical DTE.
219.
Illegal TC/Gen Clk Combination
Severity:
1
Meaning:
The software has determined that a port is set to run at an illegal line
speed (throughput class).
Action:
This is probably a configuration error. Check the Port record and
change the throughput class, if necessary.
250.
Excessively noisy line
Severity:
3
Meaning:
Self-explanatory.
Action:
Check the communications line and cables.
304.
RLP Buf Usage exceeded T:“n” C:“n”
Severity:
4
Meaning:
The RLP statistic
Percentage of Buffers in Use
has exceeded the
threshold (
T:“n”
) that was set by the user. (
C:“n”
is the current
value.)
Action:
If this happens frequently, you may need to reroute some traffic.