Configuring subscriber addresses, Configuring subscriber addresses -8, Typical svc subscriber screen -8 – Cabletron Systems 1800 User Manual
Page 176: Subscriber ids, Subscriber id, At the connections and routing paths menu, Pressing
11-8
SmartSwitch 1800 4. 0 User G uide, Rev 01
Configuring Subscriber Addresses
This operation configures the called and calling addresses that will be used in call
setup. To complete the connection, the software must recognize where the call is
coming from (calling address) and where it is going (called address).
To display a list of current Subscriber IDs (addresses), press
[A]
at the Connections and
Routing Paths Menu
(or
[A], [D], [A]
from the Main Menu).
To add or change a Subscriber ID, press
[B]
at the Connections and Routing Paths
Menu. When prompted, enter a Subscriber ID of up to 15 digits. (ID conventions are
described on
.)
Figure 11-3 Typical SVC Subscriber Screen
[A],[D],[B]
from Main Menu
Pressing
[G]
will display routing paths, which link the subscriber with one or more
ports. Pressing
[H]
will display the addresses used for call redirection. (These
addresses are valid only if
Y
is specified for one or more of items C, D, and E on the
first screen.) Parameters for all three screens are described following
Nod e Name=n odexyz
S VC Su bscrib er Maintenance
*
Sub scriber I D
0100012345
A Sub scriber N ame
su b1
B Routing Algorith m
0, Rou nd Rob in
C Systematic Redirection
N
D Redirect on Bus y
N
E Redirect on Out of Ord er
N
F Conn ection Priority
0
G Routing Paths
H Redirection A ddresses
Option: