Disable request di sconnec, Lpda support, Idle fill characte – Cabletron Systems 1800 User Manual

Page 136: Inactivi ty timer, L1-duplex, Pu name, Local subscriber id, Remote subscriber id

background image

9-10

SmartSwitch 1800 4. 0 User G uide, Rev 01

Disable Request Disconnect

prevents (if enabled) the HPAD from sending a Disconnect Request to the host if the
HPAD–TPAD connection is broken.

LPDA Support

specifies the version (if any) of Link Problem Determination Aid that can be used by
a host program (e.g., NetView or VTAM) or controller program (e.g., NCP) to test
status and to control the line and remote interface. Configurable values are:

0

(None),

1

(Version 1), and

2

(Version 2).

Idle Fill Character

specifies a character that will be inserted into the stream when the SNA link is idle.

Inactivity Timer

determines how long the SmartSwitch 1800 will wait with no activity on the HPAD
port before it will declare the port down.

L1-Duplex

determines level-1 signal operation on RS-232 ports. If

Full

, RTS, CTS, DCD are

always high (and are raised by the appropriate side). If

Half

:

When the DTE is ready to transmit, it asserts RTS, waits for CTS to become
high, then starts transmitting. When transmission is finished, the DTE drops
RTS (and the DCE should drop CTS). DCD is low during this period.

When the DCE is ready to transmit, it checks to see that RTS and CTS are not
high, then it raises DCD and starts transmitting. When transmission is done, the
DCE drops DCD. RTS and CTS are low during this period.

For both Full and Half L1-Duplex, the DTE raises DTR and the DCE raises
DSR. The link is considered up when both DTR and DSR are high.

Make sure this parameter is configured correectly, or the PU will

not become active.

PU Subscriber Parameters

PU Name

identifies the PU to an SNMP or NetView host.

identifies the PU to an SNMP or NetView host.

Local Subscriber ID

identifies the local device. A

Subscriber ID

record (see page 9-14) must also be con-

figured for this ID.

Remote Subscriber ID

identifies the remote device. A

Subscriber ID

record (see page 9-14) must also be con-

figured for this ID.

If the PU is one end of a connection to a logical X.25 port in the SmartSwitch, this
address must match a Subscriber ID configured for the logical port.