12-8

SmartSwitch 1800 4. 0 User G uide, Rev 01

Profile Name

is a name given to the async PAD's "

profile

." If login is not required (as determined in

the Port record), the profile specified in Port record is always in effect. If login is
required, the profile specified in the PAD Login record becomes effective at login,
even if it is different from the profile specified in the Port record.

If the profile specified is not defined in the database, the default profile,

90

, will be in

effect. (See "

Configuring Async PAD Profiles

" on page 12-2.)

Configuring Async Port Records

Once the necessary Node, Line Processor, and protocol parameters have been con-
figured, press

[A]

at the Port Configuration Menu (or

[A], [C], [A]

from the Main Menu.

When prompted, enter a port number (or press

[Enter]

to accept the default of

0

). Valid

port numbers depend on the model of SmartSwitch 1800—see port locations on

page 6-1

.

The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See

Table 12-3

on page 12-

9.) The following figure is an example of an existing port.

Figure 12-2 Async PAD Port Screen

[A],[C],[A]

from Main Menu

If a record does not exist for the async PAD profile identified by

Initial

Profile Name

, the letter

U

will be displayed preceding the name in the

Database

column.

After making any changes, be sure to press

[F7]

to update the

system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.

N ode Name=n odexyz

A sync PA D Port Parameters
*

Port: 0

Link State: Linku p

*

I/O:–R S-232

D atabase

Sys tem Memory

A Port Type

A sync PAD

As ync PAD

B Ph ysical Port I nterface

R S-232

RS -232

C Blocked Port Flag

N

N

D X.3 Line S peed

au tobaud

autob aud

E Initial Profile Name

90

90

F Login R eq uired

N

N

G Parity

0,none

0,none

H DCE Cab le A ttach ed

N

N

I

Mas k Lin k A larms

N

N

J

X.25 Parameter Options

K Autocall Options
L Brow se Profile
M Mod em Signal Options
N Disconnect Options
O Asyn c PAD Op tion s

Option: