Supported commands, Display commands – Cabletron Systems 1800 User Manual
Page 415

Net View Management
D-3
Supported Commands
The syntax of a
RUNCMD
from NetView is generally as follows:
RUNCMP SP=OLXPu, APPL=NVOperid, command
where:
OLXPu
is the VTAM PU name of the SmartSwitch 1800 (NetView sees the
SmartSwitch 1800 as a PU),
NVOperid
is the ID of the NetView operator issuing the command, and
command
is the text of command sent to the SmartSwitch 1800.
The
command
part of the
RUNCMD
is the only part that needs to be entered by a Smart-
Switch 1800 operator performing local access operations. Supported commands are
described over the next few pages.
Most of the commands include
{linename[n|n|n],puname}
in the format.
linename
from the first screen of the SNA Port record,
[n|n|n]
are options that can be specified if a line name was entered, and
puname
is
the
from the PU Parameters screen of the SNA Port record.
Display Commands
DISPLAY ID
Function: Displays the active/inactive status of specified PUs.
Command:
D NET, ID={linename[,A|E|I|N], puname}
Options:
A
= all active PUs on the line.
E
= all PUs on the line.
I
=
all inactive PUs on the line.
N
= only the line status (no PUs). This is the default if no option is
entered.
DISPLAY LINES
Function: Displays the active/inactive status of specified lines.
Command:
D NET, LINES[,A|E|I]
Options:
A
= all active lines.
E
= all lines. This is the default if no option is entered.
I
= all inactive lines.
DISPLAY CONFIG
Function: Displays the configuration parameters for specified PUs.
Command:
D NET, CONFIG,ID={linename[,A|E|I],puname}
Options:
A
= all active PUs on the line.
E
= all PUs on the line.
I
= all inactive PUs on the line.