beautypg.com

Cabletron Systems 1800 User Manual

Page 375

background image

Syst em Events

22-27

Action:

Check the hardware and configuration at the remote device.

717.

SDLC Rem Tx Frame exceeds MAXDATA

Severity:

2

Meaning:

A frame transmitted by the remote station exceeds the configured
value for

Maxdata

(maximum bytes per I-frame).

Action:

None.

718.

SDLC Rem sent UA in NRM

Severity:

2

Meaning:

The remote station sent a UA while in Normal Response Mode,
which is not allowed.

Action:

None.

720.

SDLC No DSR on link

Severity:

2

Meaning:

A necessary DSR was not received from the DCE.

Action:

Check the modem to make sure it is operational.

721.

SDLC No CTS on link

Severity:

2

Meaning:

A necessary CTS was not received from the DCE.

Action:

Check the modem to make sure it is operational.

722.

SDLC No External CLock

Severity:

2

Meaning:

The necessary clock is not being provided.

Action:

Check the modem to make sure it is operational.

736.

SDLC LLC/2 Remote Link Stn lost

Severity:

2

Meaning:

The remote station is not responding. Either the Inactivity Timer (

Ti

)

or Acknowledgment Timer (

T2

) has expired.

Action:

Check the remote station to make sure it is operational.

737.

LLC/2 DM Received

Severity:

2

Meaning:

The remote station sent a Disconnect Mode response, and the logical
link is down.

Action:

None.

738.

LLC/2 SABME Received when open

Severity: