beautypg.com

Cabletron Systems 1800 User Manual

Page 371

background image

Syst em Events

22-23

541.

DLCI “n” Frame Relay Header Invalid

Severity:

3

Meaning:

The header contained an invalid DLCI.

Action:

Check the configuration record for the port.

542.

DLCI “n” PVC does not exist

Severity:

3

Meaning:

Self-explanatory.

Action:

Create a PVC record.

543.

DLCI “n” Frame Discarded - CIR

Severity:

3

Meaning:

A frame was discarded, probably because the excess burst size (B

E

)

was exceeded.

Action:

The frame must be resent.

545.

DLCI “n” frame relay PVC deleted

Severity:

4

Meaning:

Self-explanatory.

Action:

None.

546.

DLCI “n” frame relay PVC connected

Severity:

4

Meaning:

Self-explanatory.

Action:

None.

547.

DLCI “n” Data Received on Inactive PVC

Severity:

3

Meaning:

One end of the PVC is probably not up.

Action:

Check both ends of the PVC.

548.

DLCI “n” No STATUS ENQ Received

Severity:

3

Meaning:

No Status Enquiry was received when one was expected.

Action:

Check the remote device.

561.

LLC Interface File Upd:LLC2IPAR.DAT

Severity:

4

Meaning:

The LLC2 Interface file has been updated.

Action:

None.