beautypg.com

Configuring a serial or voice port, Configuring a serial or voice port -2, Default configuration screen for new port -2 – Cabletron Systems 1800 User Manual

Page 65: Then

background image

Configuring Physical Ports

6-3

Configuring a Serial or Voice Port

Before configuring a physical port, make sure that the following have been properly
configured:

Node parameters

. See

Chapter 4

. This is general configuration that must be done

no matter which protocols will be run in the node.

Protocol(s)

that will be transmitted over the physical port and any logical ports

on the physical port. See

Chapter 5

.

Once these necessary records have been configured, press

[A]

(

Configuration

), then

[C]

(

Configure Ports

), then

[A]

from the Main Menu. When prompted, enter a port number

in the range

0–7

(noting the port descriptions following

Figure 6-1

and

Figure 6-2

).

(Pressing

[Enter]

without entering a number will accept the default of

0

).

Voice ports can also be configured in

Voice Application Configuration

(

[A], [C], [D]

from the Main Menu). Also, remember that Voice port 1 is con-

figured in the database as port 4, and Voice port 2 is configured as port 5.

The display for an existing record will show the configured parameter values, while
the display for a new record will show values stored in a default database record. The
following figure is an example of a new record.

Figure 6-3 Default Configuration Screen for New Port

[A],[C],[A]

from Main Menu

R mtid =nod exyz

X.25 Port Parameters (s creen 1 of 6)
*

Port: 0

Lin k State:

Lin k_disab le

*

I /O: UN IVER SAL

Databas e

A Port Type

X.25

B Phys ical Port In terface

V.35

C Blocked Port Flag

N

D Line Speed

9600 b ps

E Modu lo

8

F Maximum LA PB Window Size

7

G N 2 R etransmit Coun t

5

H T1 Retran smit Period (msec)

2000

I

T2 Wait Ack Period (ms ec)

1000

J

T3 Link Alive Period (sec)

10

K Logical DCE

N

L Generate C lock

N

M R cv Clock (TT) from DTE

N

Option: