Configuring a serial or voice port, Configuring a serial or voice port -2, Default configuration screen for new port -2 – Cabletron Systems 1800 User Manual
Page 65: Then
Configuring Physical Ports
6-3
Configuring a Serial or Voice Port
Before configuring a physical port, make sure that the following have been properly
configured:
●
. See
. This is general configuration that must be done
no matter which protocols will be run in the node.
●
that will be transmitted over the physical port and any logical ports
.
Once these necessary records have been configured, press
[A]
(
Configuration
), then
[C]
(
Configure Ports
), then
[A]
from the Main Menu. When prompted, enter a port number
in the range
0–7
(noting the port descriptions following
and
Figure 6-2
).
(Pressing
[Enter]
without entering a number will accept the default of
0
).
Voice ports can also be configured in
Voice Application Configuration
(
[A], [C], [D]
from the Main Menu). Also, remember that Voice port 1 is con-
figured in the database as port 4, and Voice port 2 is configured as port 5.
The display for an existing record will show the configured parameter values, while
the display for a new record will show values stored in a default database record. The
following figure is an example of a new record.
Figure 6-3 Default Configuration Screen for New Port
[A],[C],[A]
from Main Menu
R mtid =nod exyz
X.25 Port Parameters (s creen 1 of 6)
*
Port: 0
Lin k State:
Lin k_disab le
*
I /O: UN IVER SAL
Databas e
A Port Type
X.25
B Phys ical Port In terface
V.35
C Blocked Port Flag
N
D Line Speed
9600 b ps
E Modu lo
8
F Maximum LA PB Window Size
7
G N 2 R etransmit Coun t
5
H T1 Retran smit Period (msec)
2000
I
T2 Wait Ack Period (ms ec)
1000
J
T3 Link Alive Period (sec)
10
K Logical DCE
N
L Generate C lock
N
M R cv Clock (TT) from DTE
N
Option: