SmartSwitch 1800 4. 0 User G uide, Rev 01

Configuring an SNA Port

Once the necessary Node (

Chapter 4

) and RLP (

Chapter 5

) parameters have been con-

figured, press

[A]

at the Port Configuration Menu (or

[A], [C], [A]

from the Main Menu.

When prompted, enter a port number (or press

[Enter]

to accept the default of

0

). Valid

port numbers depend on the model of SmartSwitch 1800—see port locations on

page 6-1

.

The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See

Table 9-1

and

Table 9-2

.) The following figure is an example of an existing port.

Figure 9-2 SNA Port Screen 1

[A],[C],[A]

from Main Menu

After making any changes, be sure to press

[F7]

to update the

system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.

After configuring the above screen, press

[O]

to display a second screen. (The param-

eters for both screens are listed in

Table 9-1

on page 9-6.)

You must also define the PUs (physical units) that will communicate via the SNA port.
Once the

Additional SNA Port Parameters

are configured, press

[F3]

to return to Figure

9-2, then press

[P]

,

[A]

to display a list of configured PUs, or

[P]

,

[B]

to configure a PU.

If configuring a PU, enter (when prompted) an

SDLC PU Station Address

:

01–FE

(hex).

This address identifies the PU you are configuring, and must match the

ADDR

parameter set in the macro PU in the VTAM configuration. (The station address is
usually set to

C1

for point-to-point SDLC lines, and in series

C1, C2, C3

, etc. for mul-

tidrop lines.)

N ode Name=n odexyz

S NA Port Parameters
*

Port 0

Link State

Linku p

*

I/O: UN IVER SAL

D atabase

Sys tem Memory

A Port Type

S NA

SN A

B Name

s na1

sn a1

C Ph ysical Port I nterface

V .35

V.35

D Blocked Port Flag

N

N

E Lin e Sp eed

64k bp s

64k bp s

F No Data Poll Period (ms )

40

40

G No Resp Poll Period (ms)

2000

2000

H Maximum Retransmiss ion s

5

5

I

Ou tstand in g Frames

7

7

J

Generate Clock

Y

Y

K Rcv C lock (TT) from D TE

N

N

L SNA Typ e

2 hpad

2 hpad

M NRZ

Y Y

N Packet Size

1024

1024

O Add itional SNA Port Parameters
P SDLC PU Op erations

Option: