Cabletron Systems 1800 User Manual
Page 279
![background image](/manuals/61092/279/background.png)
Introduction to Syst em Operation
18-3
G
– Cancels the
Quiesce a Port
command (only if there are
still active connections on the port).
H
– Unquiesces a specified group of same-type
ports.
C On-Line Database Operations
– (Chapter 19) backs up database and/or system
files locally or remotely.
A
Back up the Current Database to a Remote FRX6000
B
Back up the Current Database to a Remote FRX4000/SmartSwitch 1800
C
Restore the Backed-Up Database to a Remote FRX4000/SmartSwitch 1800
D
Back up the Database to a Local Directory
E
Restore the Database from a Local Directory
F
Back Up the Current System Files to a Local Directory
G
Restore the System Files from a Local Directory
D
Test X.25 Address Translation Templates
– (Chapter 8) Tests templates to
assure they were correctly created.
E
Re-Load Initialization to Async Console
– (Chapter 19) Sends default terminal
settings to an Auxiliary Console on the node's Console port.
F
– (Chapter 19) Uses the Ping function to determine
whether an IP host is reachable.
G On-Line SDLC PU Operations
A
– Takes any SDLC PU in the node off line.
B
– Takes a group of PUs off line.
C
– Brings any SDLC in the node on line.
D
– Brings a group of PUs on line.
H
– (Appendix D) allows a NetView manager to obtain
information on the node via NMVT commands or from files in the node
database.
I
CSU/DSU Tests
– (Chapter 19) (valid only if the internal CSU/DSU port is
installed).
A
– transmits a test pattern to the analog portion of the circuitry and
loop the pattern back to itself.
B
– transmits a PRBS (pseudo-random bit sequence)
test pattern to the remote device, which will loop the signals back.
J
Frame Relay Backup Operations
– (
) allows manual switching from
a primary frame relay DLCI to its backup, or from the backup to the primary.
A
Initiate Switching Primary DLCI Over to its Backup
B
Initiate Switching DLCI Back to the Primary
C
Status Displays
A
– displays performance and link status for the node.
B
– displays port type, operational status, and link states for all ports
on the node.
C
– displays DLCIs/LCNs, link states, subscribers, and
(frame relay only) performance for all logical connections.
D
– displays configuration data for each port in the node, and shows
on/off status of each signal at the interface.
E Traffic Monitor
A
– displays control and information data of all level-3 packets
passing through a specified port.
B
LAN Capture Status and Control Menu
– allows configuration of parameters
that specify information to be captured when monitoring LAN traffic.
C
– displays captured LAN monitor information.