beautypg.com

Cabletron Systems 1800 User Manual

Page 279

background image

Introduction to Syst em Operation

18-3

G

Unquiesce a Port

– Cancels the

Quiesce a Port

command (only if there are

still active connections on the port).

H

Unquiesce a Range of Ports

– Unquiesces a specified group of same-type

ports.

C On-Line Database Operations

– (Chapter 19) backs up database and/or system

files locally or remotely.

A

Back up the Current Database to a Remote FRX6000

B

Back up the Current Database to a Remote FRX4000/SmartSwitch 1800

C

Restore the Backed-Up Database to a Remote FRX4000/SmartSwitch 1800

D

Back up the Database to a Local Directory

E

Restore the Database from a Local Directory

F

Back Up the Current System Files to a Local Directory

G

Restore the System Files from a Local Directory

D

Test X.25 Address Translation Templates

– (Chapter 8) Tests templates to

assure they were correctly created.

E

Re-Load Initialization to Async Console

– (Chapter 19) Sends default terminal

settings to an Auxiliary Console on the node's Console port.

F

IP Ping Connectivity Test

– (Chapter 19) Uses the Ping function to determine

whether an IP host is reachable.

G On-Line SDLC PU Operations

(Chapter 9)

A

Disable an SDLC PU

– Takes any SDLC PU in the node off line.

B

Disable a Range of SDLC PUs

– Takes a group of PUs off line.

C

Enable an SDLC PU

– Brings any SDLC in the node on line.

D

Enable a Range of SDLC PUs

– Brings a group of PUs on line.

H

NetView Access

(Appendix D) allows a NetView manager to obtain

information on the node via NMVT commands or from files in the node
database.

I

CSU/DSU Tests

(Chapter 19) (valid only if the internal CSU/DSU port is

installed).

A

Self Test

– transmits a test pattern to the analog portion of the circuitry and

loop the pattern back to itself.

B

Pattern Generation Test

– transmits a PRBS (pseudo-random bit sequence)

test pattern to the remote device, which will loop the signals back.

J

Frame Relay Backup Operations

– (

Chapter 19

) allows manual switching from

a primary frame relay DLCI to its backup, or from the backup to the primary.

A

Initiate Switching Primary DLCI Over to its Backup

B

Initiate Switching DLCI Back to the Primary

C

Status Displays

(Chapter 20)

A

Node Status

displays performance and link status for the node.

B

Port Status

displays port type, operational status, and link states for all ports

on the node.

C

Virtual Connections

– displays DLCIs/LCNs, link states, subscribers, and

(frame relay only) performance for all logical connections.

D

Port Signals

– displays configuration data for each port in the node, and shows

on/off status of each signal at the interface.

E Traffic Monitor

A

Port Monitor

– displays control and information data of all level-3 packets

passing through a specified port.

B

LAN Capture Status and Control Menu

– allows configuration of parameters

that specify information to be captured when monitoring LAN traffic.

C

LAN Capture Review

– displays captured LAN monitor information.