Syst em Events
22-25
644.
Fr RLP/PORT/DLCI Mismatch
Severity:
3
Meaning:
A mismatch has occurred between the current configuration and the
requested RLP/Port/DLCI when configuring a frame relay based IP
or IPX interface.
Action:
Change the requested RLP/Port/DLCI.
701.
SDLC Rem. Link Stn Not Responding
Severity:
2
Meaning:
Self-explanatory. (
Rem Link Stn
is the Remote Link Station.)
Action:
Check the PU to make sure it is operational.
702.
SDLC Link Stn Sent DM
Severity:
2
Meaning:
The link station sent a Disconnect Mode response, and the logical
link is down.
Action:
None.
704.
SDLC Link Stn rcvd FRMR, Inv. cmd
Severity:
2
Meaning:
The remote device received an invalid command and responded
with a Frame Reject.
Action:
None.
705.
SDLC Stn rcvd FRMR, IFLD invalid
Severity:
2
Meaning:
The remote device received an unpermitted I frame and responded
with a Frame Reject.
Action:
None.
706.
SDLC Stn rcvd FRMR, Nr invalid
Severity:
2
Meaning:
The remote device received a frame with an invalid N(r) and
responded with a Frame Reject.
Action:
None.
707.
SDLC Stn rcvd FRMR, Ifld too long
Severity:
2
Meaning:
The remote device received an I frame that was too long, and
responded with a Frame Reject.
Action: