Pad profile parameters, Pad profile parameters -3, Async pad profile parameters -3 – Cabletron Systems 1800 User Manual
Page 181: Be sure to specify these as different characters, Escape is not allowed, Escape will be initiated by
Configuring Async Ports
12-3
PAD Profile Parameters
The numbers preceding the parameter names correspond to CCITT
X.3. Also, the default values make up CCITT profile 90.
When specifying characters that will perform functions (i.e.,
Data Forwarding
or
Character Delete
), be sure to specify these
as different characters
Profile Description
is used simply as an identifier. It is not an X.3 parameter.
01, PAD Recall
allows the user's device to initiate an escape from data transfer or connection in
progress state in order to send PAD command signals. Values (can be added) are:
0
= escape is not allowed.
1
= escape will be initiated by
[Ctrl] [P]
(
1/0
),
Data Link Escape
.
32–126
= escape will be initiated by the character defined by this number.
Table 12-1 Async PAD Profile Parameters
Parameter
Valid Values
Default Value
1–31 uppercase chars.
none
0–126
1
0
(no) /
1
(yes)
1
0–127
126
( sec)
0–255
0
0–2
1
0–15
1
0–31
2
0
(no) /
1
(yes)
0
0–255
(characters)
0
0–255
0
n/a–determined in Port configration
0
(no) /
1
(yes)
1
0–7
0
0–255
(characters)
0
0
(no) /
1
(yes)
0
0–127
127
0–127
24
0–127
18
0–126
1
0–255
0
0–3
0
0–255
(linefeeds)
0