Event generation, Displaying events, Event generation -3 displaying events -3 – Cabletron Systems 1800 User Manual
Page 351: Playing events

Syst em Events
22-3
Event Generation
As soon as a message-generating event occurs, a Call Request is automatically sent to
the
, and the
if configured. (The
event is stored in the originating node's buffer until the event connection is activated.)
All events are transmitted in raw data format to the collecting node, which constructs
event messages and sends them to the display device(s).
An internal timer limits the time events are kept in the system buffer if the system fails
to bring the event connection up. If the timer expires, the buffer is cleared. The event
connection remains active until the event system detects that there are no events
occurring during the time period set for the
. After the event connection
is cleared, the event system will repeat the above procedures if any events occur.
Displaying Events
To display any local events on the screen as they occur, press
[D]
at the Main Menu.
Event messages will continue to be sent to any destinations specified by the param-
eters described earlier in this chapter.
While this feature is activated, you cannot perform other operations on the
screen. Also, if the Primary Alarm Output device is unreachable, no local
events will be displayed.
A display at a collecting node looks like the example shown below. (A display at a
sending node will show only that node's events.)
Chicago
1008
01/16/1998
08:34:31
end of ipl
Chicago
1013
01/16/1998
08:34:32
L:0 P:2 link PAD fail
Chicago
1004
01/16/1998
08:34:38
L:0 P:0 link X.25 fail
Chicago
1005
01/16/1998
08:34:44
L:0 P:0 restart with cc=7 dc=0
Chicago
1006
01/16/1998
08:35:15
L:0 P:0 operational
St Louis
1008
01/16/1998
08:30:43
end of ipl
St Louis
1004
01/16/1998
08:30:50
L0 P:1 link X.25 fail
St Louis
450
01/16/1998
08:31:41
St Louis
1005
01/16/1998
08:32:24
L:0 P:3 restart with cc=0 dc=0
St Louis
1006
01/16/1998
08:32:35
L0 P:3 operational
St Louis
450
01/16/1998
08:33:01
St Louis
1005
01/16/1998
08:33:14
L:0 P:1 restart with cc=0 dc=0
St Louis
1008
01/16/1998
08:33:31
end of ipl
Press
[F3]
to stop displaying events and return to normal menu operations.