beautypg.com

Bsc interactive port parameters, Bsc interactive port parameters -4, Table 10-1 – Cabletron Systems 1800 User Manual

Page 160: Table 10-1 bsc interactive port parameters

background image

10-4

SmartSwitch 1800 4. 0 User G uide, Rev 01

BSC Interactive Port Parameters

1

75, 150, 300, 600, 1200, 2400, 4800, 9600, 14.4K, 19.2K

.

2

Relevant only if

Physical Port Interface

is other than

RS-232

and

Generate Clock

is

Y

.

3

See note under

Figure 10-1

.

Table 10-1 BSC Interactive Port Parameters

Parameter

Valid Values

Default Value

Port Type

BSC-I

(not valid here)

Physical Port Interface

see explanation

see explanation

Blocked Port Flag

Y/N

N

Line Speed

75 bps – 19.2 Kbps

1

9600 bps

Retransmission Period

(ms)

1–9999

2000

Maximum Retransmissions

1–99

5

Maximum Bytes per Frame

25–4105

4105

Generate Clock

Y/N

Y

Rcv Clock (TT) from DTE

Y/N

2

N

BSC Type

1

(TPAD),

2

(HPAD)

1

Answer Non-Configured

3

Y/N

Y

Activate Connecti on w/o poll

3

Y/N

Y

EBCDIC

n/a – leave at default

Y

Cal l Info in Cal l Request Packet

n/a – leave at default

Y

Clear VC on Last Device Down

Y/N

N

Transparent Text Supported

n/a – leave at default

Y

End-to-End Acknowledgement

n/a – leave at default

N

Full Duplex

n/a – leave at default

Y

Multidrop

Y/N

N

Sl ow Poll Retry Count

10–150

20

Sl ow Poll Retry Fr equency

1–200

20

# of Beginning Sync Char

2–10

2

# of Tr aili ng Pad Characters

1–10

1

Pol l Interval Timer

(msec)

100–1000

500

No Response Ti mer

(sec)

2–10

2

No Response Retry Count

1–255

5

Er ror Retransmit Count

1–255

5

NAK Retry Count

1–255

5