13-3
Configuring Voice System-Level Parameters
Certain database parameters apply to specific ports or interfaces. Others are con-
figured only once, and apply to all voice calls on the node.
Pressing
[A]
at the Voice Configuration Menu will display a menu similar to the fol-
lowing.
Figure 13-2 Voice System-Level Configuration Menu
[A],[F],[A]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.
Table 13-1 lists the system-level parameters. Explanations of the parameters follow
the table.
Table 13-1 Voice System-Level Parameters
Parameter
Valid Values
Default Value
1–9999
1
75V/16.66Hz, 80V/20Hz, 75V/25Hz,
60V/50Hz, 75V/50Hz
80V 20Hz
0–999
1
1–4
3
(kbi ts/sec)
4. 8, 8, 32, 64
4.8
(kbits/ sec)
4. 8, 8, 32, 64
64
User Di aled Extended Dial Digits
0–16
0
N ode N ame= node_xyz
Voice S ystem-Level C onfiguration Parameters
A
Voice Node Numb er
1
B
Ring Voltage, Freq uency
80V 20.00Hz
C
Cou ntry Cod e
1
D
Sp eed Map D ial D igits
4
E
Voice Rates Minimum
8
F
Voice Rates Maximum
64
G Us er D ialed Exten ded D ial Digits
0
Op tion :