Page 170: Bsc batch port(s), After making any changes, be sure to press, At the port configuration menu (or, Pressing, Lists more parameters, and pressing
11-2
SmartSwitch 1800 4. 0 User G uide, Rev 01
Configuring BSC Batch Ports
Once the necessary Node (
) and protocol (
) parameters have been
configured, press
[A]
at the Port Configuration Menu (or
[A], [C], [A]
from the Main
Menu. When prompted, enter a port number (or press
[Enter]
to accept the default of
0
). Valid port numbers depend on the model of SmartSwitch 1800—see port locations
.
The display for an existing port will show the configured parameter values, while the
display for a new port will show default database values. (See
on page 11-
3.) The following figure is an example of an existing port.
Figure 11-1 BSC Batch Port Record
[A],[C],[A]
from Main Menu
After making any changes, be sure to press
[F7]
to update the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.
Pressing
[J]
lists more parameters, and pressing
[K]
displays a screen similar to the fol-
lowing. (All BSC Batch parameters are listed in
.)
N ode Name=n odexyz
BS C Batch Port Parameters (screen 1 of 2)
*
Port: 1
Link State: Linku p
*
I/O: V .35
Datab ase
Sys tem Memory
A Port Type
BSC Batch
BSC Batch
B Ph ysical Port I nterface
V.35
V.35
C Blocked Port Flag
N
N
D Lin e Sp eed
9600 bps
9600 bps
E Retran smission Period (ms )
2000
2000
F Maximum Retransmiss ion s
5
5
G Maximum Bytes p er Frame
4105
4105
H Generate Clock
Y
Y
I
Rcv C lock (TT) from D TE
N
N
J
Batch Parameters - Screen 2
K Sub scriber I nformation - Screen 3
Option: