St atus Displays

20-13

The format of status exchanges depends on the type of link management. Annex D
frames always use DLCI

0000

, and LMI frames always use DLCI

1023

. Examples of

both formats are shown below:

Annex D

LMI

0000 Full Status Enquiry 001/000

T 1023 Full Status Enquiry 001/000

0000 Full Status 001/001

R 1023 Full Status 001/001

016:N 017:N

141: N 241: A

0000 LIV Status Enquiry 002/001

T 1023 LIV Status Enquiry 002/001

0000 LIV Status 002/002

R 1023 LIV Status 002/002

0000 LIV Status Enquiry 003/002

T 1023 LIV Status Enquiry 003/002

0000 LIV Status 003/003

R 1023 LIV Status 003/003

0000 LIV Status Enquiry 004/003

T 1023 LIV Status Enquiry 004/003

0000 LIV Status 004/004

R 1023 LIV Status 004/004

0000 LIV Status Enquiry 005/004

T 1023 LIV Status Enquiry 005/004

0000 LIV Status 005/005

R 1023 LIV Status 005/005

0000 LIV Status Enquiry 006/005

T 1023 LIV Status Enquiry 006/005

0000 LIV Status 006/006

R 1023 LIV Status 006/006

0000 Full Status Enquiry 007/006

T 1023 Full Status Enquiry 007/006

0000 Full Status 007/007

R 1023 Full Status 007/007

016: A 017:A

141: A 241: A

0000 LIV Status Enquiry 008/007

T 1023 LIV Status Enquiry 008/007

The pair of 3-digit numbers at the end of each line are the send/receive sequence
numbers. For example,

LIV Status Enquiry 002/001

means that the DTE received

sequence 001 and sent sequence 002.

If the timestamp is turned on, it will be displayed at the left of each line. Note that the

T

or

R

in LMI frames indicates whether the frame was transmitted or received by the

port being traced.

Note that in the above example the frame relay DTE port is configured for an

N1

Polling Count

of

6

, meaning that every six polling cycles the DTE will send a Full

Status Enquiry to the DCE, asking for the status of the DLCIs on the link. The interval
between

N1

polls is governed by the frame relay port parameter

T1 Link Integrity Timer

.

If

N1

is set to 6 and

T1

is set to 10, the status of DLCIs will be reported every 60

seconds. If you are using DLCI backup, you may have to lower these parameters
(thereby learnng the DLCI status sooner) to avoid application timeouts on
switchovers. The tradeoff on this approach is more management overhead on the link,
so it is generally better to increase the applications timeout parameters.

Data Exchanges

Data packet (Q.922 UI frame) entries include the following, reading from the left:

Timestamp, if turned on.

T

or

R

, indicating whether the frame was transmitted or received by the port

being traced.

Four-digit DLCI.

Identification of any of these bits that are set:

B

– Backward Explicit Congestion Notification (BECN).

F

– Forward Explicit Congestion Notification (FECN).

D

– Discard Eligibility Indicator (DE).

C/R

– Command/Response.

Four-digit packet length, starting from the frame relay Q.922 control byte.