8-28
SmartSwitch 1800 4. 0 User G uide, Rev 01
The fields must match the equivalent fields in the Call Request packet, but not neces-
sarily literally—they can use wildcards.
Figure 8-10 Address Translation Template Screen
[A],[C],[C],[B]
from Main Menu
Translation Template Parameters
1
Used simply for ease of identification.
2
These determine the translation formula:
P
= Pass through unchanged.
R
= Remove entire field.
L
= Replace with literal digit.
X
= Replace with original called address.
G
= Replace with original calling address.
U
= Replace with original user data.
T
= Replace with ASCII text.
If replacing all or part of a field, see "Replacing (field type)" over the next few pages.
All wild cards are valid in the translation template, allowing one template to function
for many calls.
Table 8-4 Translation Template Parameters
Parameter
Valid Values
Default Value
Template Name
1
0–31 characters
none
P,R,L,X,G,U
2
P
P,R,L,X,G,U
2
P
P,R,L,X,G,U,T
2
P
P ,
0–8 characters
2
P
P ,R,
0–218 characters
2
P
N ode Name=n odexyz
Trans lation Template Maintenan ce
*
Port
3
*
Direction
I
*
Temp late ID
223*G19972U111154321*
A Temp late Name
tempexamp
B Called Ad dres s
P
C User D ata
D
D Calling Ad dres s
L12345C23U 234
E Protocol ID
P
F Facilities
P
Option: