beautypg.com

Frame relay backup examples -3, Example 1 – Cabletron Systems 1800 User Manual

Page 71

background image

FRM Conf iguring Frame Relay

7-3

Figure 7-1 Frame Relay Backup Examples

Although each example shows a connection between a SmartSwitch
1800 and an FRX6000, connections can be between any two devices
in the family of SmartSwitch 1800, Frame Relay Module (FRM),
FRX4000, and FRX6000.

Example 1

In Example 1, the primary link is between Node 1/Port 2/DLCI 16 and Node 2/RLP
0/Port 0/DLCI 18. The DLCIs should be configured as described below. (The param-
eters are described later in this chapter.) Then if the primary link goes down, a con-
nection will automatically be established between Node 1/Port 0/DLCI 17 and Node
2/RLP 0/Port 4/DLCI 17.

On Node 1, configure the following (as well as other parameters necessary for oper-
ation—this section deals only with the frame relay backup function):

1. Port Configuration (

[A], [C], [A]

from Main Menu) for the primary:

RLP: 0
RLP Port: 2

O Additional Parameters

D

Configure DLCI Parameters
DLCI ID: 16

I

DLCI Backup Configuration
A

Backup Group Number: 10

(or any unused number except

0

)

B

Enable Backup Protocol?: N

E

For Backup Use Only: N

Example 1

Node 1

Example 2

Node 1

Example 3

Node 1

2,16

0,17

0,0,18

0,4,17

Node 2

Port,DLCI

RLP,Port,DLCI

0,0,18

Node 2

2,16

0,17

2,16

0,17

0,0,18

0,4,17

Node 2

1,3,22

1,4,56

Other
Device

Other
Device