Bridge filter application parameters, Bridge filter application parameters -11, Typical bridge filter applications record -11 – Cabletron Systems 1800 User Manual
Page 263: Bridge filter applications parameters -11, Table 16-7, Determines whether the traffic defined by the
Configuring Bridging
16-11
Figure 16-3 Typical Bridge Filter Applications Record
[A],[A],[E], [F],[I]
from Main Menu
Up to 100 filters can be configured, displayed over ten "pages" (screens).
[PgDn]
and
[PgUp]
can be used to move through the screens. (At any screen, pressing
[F3]
will save
the configuration for all ten screens and exit the display. Pressing
[Esc]
at any screen
will abandon the changes for all ten screens and exit.)
When finished configuring filter definitions and applications, you must perform an
on-line update to make the changes effective immediately. Press
[J]
at the Filter Def-
initions and Applications Configuration Menu. The changes will be sent to the
software in the SmartSwitch 1800.
Bridge Filter Application Parameters
Permit
Determines whether the traffic defined by the
Filter "n"
entries will be permitted or
denied passage across the interface.
Filter "n"
corresponds to the Filter IDs in the
file.
Table 16-7 Bridge Filter Applications Parameters
Parameter
Valid Values
Default Value
Y/ N
N
0–65535
0
Nod e Name=n ode_xyz
Bridge Filter Ap plications
*
Bridge Port N umber
2
*
Filter Type
5 MA C
*
Direction
I–I nbou nd
A Permit
Y
B Filter App lication 1
0
C Filter App lication 2
0
D Filter App lication 3
0
E Filter App lication 4
0
F Filter App lication 5
0
G Filter App lication 6
0
H Filter App lication 7
0
I
Filter App lication 8
0
J
Filter App lication 9
0
K Filter App lication 10
0
Option: