beautypg.com

Bridge filter application parameters, Bridge filter application parameters -11, Typical bridge filter applications record -11 – Cabletron Systems 1800 User Manual

Page 263: Bridge filter applications parameters -11, Table 16-7, Determines whether the traffic defined by the

background image

Configuring Bridging

16-11

Figure 16-3 Typical Bridge Filter Applications Record

[A],[A],[E], [F],[I]

from Main Menu

Up to 100 filters can be configured, displayed over ten "pages" (screens).

[PgDn]

and

[PgUp]

can be used to move through the screens. (At any screen, pressing

[F3]

will save

the configuration for all ten screens and exit the display. Pressing

[Esc]

at any screen

will abandon the changes for all ten screens and exit.)

When finished configuring filter definitions and applications, you must perform an
on-line update to make the changes effective immediately. Press

[J]

at the Filter Def-

initions and Applications Configuration Menu. The changes will be sent to the
software in the SmartSwitch 1800.

Bridge Filter Application Parameters

Permit

Determines whether the traffic defined by the

Filter "n"

entries will be permitted or

denied passage across the interface.

Filter "n"

corresponds to the Filter IDs in the

Bridge Filter Definitions

file.

Table 16-7 Bridge Filter Applications Parameters

Parameter

Valid Values

Default Value

Permit

Y/ N

N

Fi lter "n"

0–65535

0

Nod e Name=n ode_xyz

Bridge Filter Ap plications

*

Bridge Port N umber

2

*

Filter Type

5 MA C

*

Direction

I–I nbou nd

A Permit

Y

B Filter App lication 1

0

C Filter App lication 2

0

D Filter App lication 3

0

E Filter App lication 4

0

F Filter App lication 5

0

G Filter App lication 6

0

H Filter App lication 7

0

I

Filter App lication 8

0

J

Filter App lication 9

0

K Filter App lication 10

0

Option: