Viewing learned dlcis (figure 7-4, item e), Viewing learned dlcis (figure 7-4, item e) -13, Frame relay dlci configuration screen 2 -13 – Cabletron Systems 1800 User Manual
Page 81: Figure 7-7, Viewing learned dlci s (figure 7-4, item e)
![background image](/manuals/61092/81/background.png)
FRM Conf iguring Frame Relay
7-13
Figure 7-7 Frame Relay DLCI Configuration Screen 2
If you configure a
Backup Group Number
,
Enable Backup Protocol
will be
replaced by several parameters (listed in
on page 7-15) that
determine backup operation.
If you change
Enable Backup Protocol
to
Y
, the
Backup Group Number
entry
will disappear.
Viewing Learned DLCIs (Figure 7-4, Item E)
If the port is a logical DTE, a list of all DLCIs (extracted from LMI/AnnexD frames)
can be displayed by pressing
[E]
. Each displayed DLCI will be followed
by three columns:—
A
,
N
, and
C
—with the following possible values:
A
:
a
= active,
i
= inactive.
N
:
n
= new,
o
= old. (A newly learned DLCI will become "old" after the first
Full Status Inquiry.
C
:
c
= configured via the DLCI configuration screen.
l
= learned through some other means (e.g., through link management
information).
Node N ame= nod e_xyz
Frame R elay D LCI Con figu ration (screen 2 of 2)
*
R LP
0
*
Port
7
*
D LCI
16
A
Backu p Group Nu mber
0
B
En able Back up Protocol
N
Op tion :