Offset Table and Setup

Chapter 3

3-23

5.

Data can be replaced or added to as follows:

To replace stored travel data with new data, key-in the new data
and press the

{REPLCE VALUE}

softkey.

To add to previously stored travel data, key-in the amount to be
added and press the

{ADD TO VALUE}

softkey.

(softkey level 4)

REPLCE

VALUE

ADD TO

VALUE

UPDATE

& EXIT

QUIT

6.

To end editing the programmable zone parameters there are two
choices.

Press the

{UPDATE & EXIT}

softkey to store the changes made to

the parameters and leave the programmable zone screen.

Press the

{QUIT}

softkey to delete all changes made to the

programmable zones and leave the programmable zone screen.

(softkey level 4)

REPLCE

VALUE

ADD TO

VALUE

UPDATE

& EXIT

QUIT

Use this feature to change the values set for the single digit feedrates.
When a single digit F--word is encountered during block execution, the
control looks to the single digit feedrate table for a feedrate. The feedrate
in this table corresponding to the single digit then becomes the active
feedrate. For details on programming single digit F--words see chapter 28.

Important: Feedrates must always be entered into the single digit feedrate
table in units of inches per minute (IPM) or millimeters per minute
(MMPM) dependent on the controls current feedrate mode.

1.

Press the

{SYSTEM SUPORT}

softkey.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

3.6
Single Digit Feedrate Table