6 single digit feedrate table – Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual
Page 97
Offset Table and Setup
Chapter 3
3-23
5.
Data can be replaced or added to as follows:
To replace stored travel data with new data, key-in the new data
and press the
{REPLCE VALUE}
softkey.
To add to previously stored travel data, key-in the amount to be
added and press the
{ADD TO VALUE}
softkey.
(softkey level 4)
REPLCE
VALUE
ADD TO
VALUE
UPDATE
& EXIT
QUIT
6.
To end editing the programmable zone parameters there are two
choices.
Press the
{UPDATE & EXIT}
softkey to store the changes made to
the parameters and leave the programmable zone screen.
Press the
{QUIT}
softkey to delete all changes made to the
programmable zones and leave the programmable zone screen.
(softkey level 4)
REPLCE
VALUE
ADD TO
VALUE
UPDATE
& EXIT
QUIT
Use this feature to change the values set for the single digit feedrates.
When a single digit F--word is encountered during block execution, the
control looks to the single digit feedrate table for a feedrate. The feedrate
in this table corresponding to the single digit then becomes the active
feedrate. For details on programming single digit F--words see chapter 28.
Important: Feedrates must always be entered into the single digit feedrate
table in units of inches per minute (IPM) or millimeters per minute
(MMPM) dependent on the controls current feedrate mode.