Message
Description
MINIMUM RPM LIMIT AUXILIARY SPINDLE 2
The commanded aux spindle 2 speed requested by the control is less than the AMPed minimum
aux spindle 2 speed for the current gear being used. This requires a gear change operation or a
change in the programmed aux spindle 2 speed. In some cases, the
MINIMUM RPM LIMIT AUXILIARY SPINDLE 3
The commanded aux spindle 3 speed requested by the control is less than the AMPed minimum
aux spindle 3 speed for the current gear being used. This requires a gear change operation or a
change in the programmed aux spindle 3 speed. In some cases, the
MINIMUM RPM LIMIT FIRST SPINDLE
The commanded spindle 1 speed requested by the control is less than the AMPed minimum
spindle 1 speed for the current gear being used. This requires a gear change operation or a
change in the programmed spindle 1 speed. In some cases, the
MINIMUM RPM LIMIT PRIMARY SPINDLE
The commanded primary spindle speed requested by the control is less than the AMPed
minimum primary spindle speed for the current gear being used. This requires a gear change
operation or a change in the programmed primary spindle speed. In some cases, the
MINIMUM RPM LIMIT SECOND SPINDLE
The commanded spindle 2 speed requested by the control is less than the AMPed minimum
spindle 2 speed for the current gear being used. This requires a gear change operation or a
change in the programmed spindle 2 speed. In some cases, the
MINIMUM RPM LIMIT THIRD SPINDLE
The commanded spindle 3 speed requested by the control is less than the AMPed minimum
spindle 3 speed for the current gear being used. This requires a gear change operation or a
change in the programmed spindle 3 speed. In some cases, the
MIRROR NOT ALLOWED ON ROLLOVER AXIS
You cannot perform mirrored motion using an axis with rollover.
MISSING 1394 I/O RING ADDR
This message indicates that a 1394 amplifier ID has been AMPed but not defined in I/O ring
assignment from ODS. The 1394 amplifier must be a defined device on the 9/Series fiber optic
I/O ring.
MISSING ( [ ) AFTER FUNCTION NAME
Paramacro and calculator functions must have their values enclosed in [ ], for example, SIN[5].
MISSING ( ] )
Paramacro and calculator functions must have their values enclosed in [ ], for example, SIN[5].
The control has found that a right bracket “]”is missing in the current operation.
MISSING (END) COMMAND
The control has found an end-of-program block (M02 or M30) before it has read the END
command for a paramacro DO loop.
MISSING (F) IN INVERSE TIME
An F-word must be programmed in every motion block that is not rapid when in inverse time
feed mode (G93). F is not modal in G93.
MISSING (GOTO) COMMAND
An IF paramacro condition does not have a GOTO with a sequence number following the
condition.
MISSING A (DO) COMMAND
A WHILE paramacro condition does not have a DO with a loop identifier following the condition.
MISSING ADAPTIVE FEED DATA
An attempt was made to create a transfer line part program from the quick view screen with
incomplete adaptive feedrate data.
MISSING COMMA
An error occurred in G05 DH+ communications block.
MISSING COMMA OR RIGHT PARENTHESIS
An error occurred in G05 DH+ communications block.
MISSING CUTTER COMP CODE
Cutter compensation must be activated before initiating a G89 irregular pocket cycle.
MISSING DATA FROM BLOCK
G89 irregular pocket cycle parameters are missing from a the G89 programming block.
MISSING END PARENTHESIS
An error occurred in G05 DH+ communications block.
MISSING G67
An active modal macro (G66 or G66.1) was not canceled by a G67 before the control read an
M02 or M30 end-of-program command.
MISSING HPG FROM I/O RING
The I/O assignment file that was compiled and downloaded with PAL defines an HPG that is not
physically present in the I/O ring. Verify that the HPG address settings are correct.