Error and System Messages
Appendix B
B-19
Message
Description
INCOMPATIBLE TOOL ACTIVATION MODES
This message is displayed and the control is held in E-Stop at power up when the tool geometry
offset mode is “Immediate Shift/Immediate Move”and the tool wear offset mode is “Immediate
Shift/Delay Move” or when the tool geometry offset mode is “Immediate Shift/Delay Move”and
the tool wear offset mode is “Immediate Shift/Immediate Move”. These modes are incompatible.
You must correct your AMP configuration and re-download AMP.
INCORRECT NUMBER OF SYMBOLS
An error occurred in G05 DH+ communications block.
INPUT DATA TOO LONG
The data input has a number of characters exceeding the allowable number of characters.
INPUT STRING SYNTAX ERROR
An attempt was made to search for an illegal character string, or no character string was
entered.
INSUFFICIENT MEMORY FOR PAL PROGRAM
An attempt was made to load a PAL program that exceeded the PAL storage space limit allotted
by the flash memory.
INSUFFICIENT MEMORY FOR PART PROGRAM
There is not enough available memory for the current program to be stored. Any attempt to
store the program in memory will be aborted by the control.
INTEGRANDS FOR DUALS MUST BE THE SAME
This is a power turn-on message. When using dual axes, all integrands of the dual group must
use the same letter.
INTEGRANDS FOR NON-MASTER MUST BE NONE
An axis integrand name was configured in AMP that corresponds to an axis in a dual axis group
that is not the master axis of that group. Only the master axis in a dual axis group can have a
corresponding axis integrand name.
INTEGRANDS NOT AMPED PROPERLY
The axis integrand names were not configured properly in AMP. Refer to your AMP manual for
additional details on axis integrand names.
INTERF CHECKING ZONE TABLE CORRUPTED
The zone tables used by interference checking have an invalid checksum and were cleared.
INTERNAL COMMUNICATIONS ERROR
Communication failed. Contact Allen-Bradley customer support services.
INTERRUPT NOT RECOGNIZED
An interrupt macro was not acted on for some reason. An example would be if an interrupt
occurred in the middle of another interrupt.
INVAL LOOP BASE
An attempt was made to configure ports TB2 and TB3 as postion/velocity loop or digital or digital
spindle.
INVALID AMP-DEFINED G CODE
An attempt was made to assign the same G-code to different macro calls. This message
appears after AMP is downloaded and the control does secondary calculations.
INVALID AMP LETTER FORMAT
The programmed word or parameter has an invalid letter format defined in AMP. Since ODS
AMP detects and prohibits invalid formats, this error usually indicates that an invalid format was
entered through patch AMP. Refer to your AMP reference manual for details.
INVALID ARC-COSINE ARGUMENT
An attempt was made to calculate or execute a paramacro block that calculates the arc cosine
of an invalid or improperly entered number.
INVALID ARC-SINE ARGUMENT
An attempt was made to calculate or execute a paramacro block that calculates the arc sine of
an invalid or improperly entered number. Change cosine to sine.
INVALID ARGUMENT ASSIGNMENT
An invalid argument assignment was programmed.
INVALID AXIS
The axis programmed in the adaptive depth (G26) or adaptive feedrate (G25) block is invalid.
Valid axis names for programming these features are defined in AMP.
INVALID AXIS FOR CSS
The CSS axis (the axis that is perpendicular to the center-line of the rotating part) is not a valid
axis on the control. This usually occurs when the CSS axis is changed from the default axis by
programming a P-word in the G96 block that selects some other axis.
INVALID AXIS PROGRAMMING RESOLUTIONS
The axis resolutions set in AMP by the system installer are too far apart. The control is
incapable of handling large differences in axis resolutions. For example, if the X axis has a
resolution that allows .999999 and the Z axis allows a resolution of only .9, the control can have
difficulty moving both axes simultaneously.
INVALID CCT INDEX
An error occurred in G05 DH+ communications block.
INVALID CHANNEL NAME
An error occurred in G05 DH+ communications block.
INVALID CHARACTER
A program name has been entered that contains an illegal special character.