beautypg.com

Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual

Page 185

background image

Running a Program

Chapter 7

7-3

To enter a sequence number to stop execution:

1.

Press the {PRGRAM MANAGE} softkey. Note that a program must
have already been selected for automatic execution as discussed in
section 7.3.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

2.

Press the {ACTIVE PRGRAM}.

REFORM

MEMORY

ACTIVE

PRGRAM

EDIT

PRGRAM

RESTRT

PRGRAM

DISPLY

PRGRAM

COPY

PRGRAM

VERFY

PRGRAM

PRGRAM

COMENT

DELETE

PRGRAM

RENAME

PRGRAM

INPUT

DEVICE

(softkey level 2)

3.

Press the {SEQ STOP} softkey.

(softkey level 3)

DE-ACT

PRGRAM

SEARCH MID ST

PRGRAM

T PATH

GRAPH

T PATH

DISABL

SEQ

STOP

TIME

PARTS

4.

Key in the sequence number where automatic operation in the part
program is to stop, then press the [TRANSMIT] key.

Important: The control will stop automatic operation after it completes
the commands in the block.

5.

Press the button to continue execution of the
program from the point at which program execution was stopped.