4 verifying part programs against source programs – Rockwell Automation 8520-MUM 9/Series CNC Mill Operation and Programming Manual Documentation Set User Manual
Page 273
Communications
Chapter 9
9-17
To verify that a part program stored in memory matches a source program
stored in memory or on a peripheral device:
1.
If one of the programs to either verify or verify against is on a
peripheral device, make sure that the peripheral device is connected
to the correct serial port and that the port is configured for that device
(see section 9.1.1).
2.
Press the {PRGRAM MANAGE} softkey.
(softkey level 1)
PRGRAM
MANAGE
OFFSET MACRO
PARAM
QUICK
CHECK
SYSTEM
SUPORT
FRONT
PANEL
ERROR
MESAGE
PASS-
WORD
SWITCH
LANG
3.
Press the {VERIFY PRGRAM} softkey.
REFORM
MEMORY
ACTIVE
PRGRAM
EDIT
PRGRAM
RESTRT
PRGRAM
DISPLY
PRGRAM
COPY
PRGRAM
VERIFY
PRGRAM
PRGRAM
COMENT
DELETE
PRGRAM
RENAME
PRGRAM
INPUT
DEVICE
(softkey level 2)
4.
Type program name(s) into the input area (lines 1- 2) in the following
manner. If both programs are resident in control memory, type both
program names separated by a comma. The order in which these
names are entered is not important.
VERIFY: program name,program name
If one of the programs to verify is on a peripheral device and the
other is resident in control memory, it is only necessary to type the
name of the program resident in the control.
VERIFY: program name
9.4
Verifying Part Programs
Against Source Programs