beautypg.com

Relay testing – SkyTrak 6042 Service Manual User Manual

Page 513

background image

10.7

Model 6042 Legacy

Origin 7/02

Stabil-TRAK™ System

10.3.3

Relay Testing

If after checking the electrical system, a relay is suspect,
test the relay as follows:

1. Park the vehicle on a firm, level surface. Level the

vehicle, ground the attachment, place the travel select
lever in the (N) NEUTRAL position, place the neutral
lock lever in the (N) NEUTRAL LOCK position, engage
the parking brake switch and shut the engine OFF.

2. Place an Accident Prevention Tag on both the

ignition key switch and steering wheel, stating that
the vehicle should not be operated. (Refer to Section
1.5, “Accident Prevention Tag Usage.”)

3. Disconnect the battery negative (-) cable

(Fig. 10 -10, 1) at the battery negative (-) terminal.

Figure 10-10 Disconnect the Battery Negative (-) Cable

4. The fuse panel is mounted behind the right side

console panel (Fig. 10 -11, 1). To gain access,
remove the four button-head screws (2) and remove
the console panel (1).

Figure 10-11 Remove the Console Panel

5. Remove the relay from the fuse panel.

6. Apply 12 volts to terminal 86 (Fig. 10-12 and

Fig. 10-13, 1) and attach the ground (-) probe to
terminal 85 (2). An audible click should be heard,
indicating the relay is functioning properly.

Figure 10-12 Relay Terminals

Figure 10-13 Relay Internal Components

OH2420

1

OH2430

2

1

~

86

85

30

87

87A

MN1820

1

2

87A

87

86

85

30

MT3140

2

1