West Control Solutions KS98-1 User Manual
Page 182
Digital outputs:
et-err
0 = no engineering error
1 = engineering error (several module blocks at a slot output).
slots not connected.
slotId
0 = correct slot allocation
1 = faulty slot allocation (module type). Faulty coupler module
valid
0 = no data
1 = data could not be received
fail 1 faulty connection or measurement error on channel 1
fail 2 faulty connection or measurement error on channel 2
ready ready message after command handling
Analog inputs:
connection of one of the slot outputs of the RM201-1-node block
Analog outputs:
AI 1
1st measured value of strain gauge channel 1
AI 2
2nd measured value of strain gauge channel 2
Parameters:
MTyp 1/2
module type 0: RM225 = strain gauge
STyp 1/2
0: -4 +4mV/V
Unit 1/2
mV/V
Tf 1/2
filter time constant input 1 ... 2 in (s) 0 ... 999 999 (0,5
)
x0 1/2
scaling start value input 1 ... 2 -29 999 ... 999 999 (0)
x100 1/2
scaling end value input 1 ... 2 -29 999 ... 999 999
(100)
Fail 1/2
signal action in case of sensor error
0:upscale
1:downscale
X1in 1/2
measured value correction input value
segment point 1 > input 1...2 -29 999 ... 999 999
(0)
X1out 1/2 measured value correction output value
segment point 1 > input 1...2 -29 999 ... 999 999
(0)
X2in 1/2
measured value correction input value
segment point 2 > input 1...2 -29 999 ... 999 999
(100)
X2out 1/2 measured value correction output value
segment point 2 > input 1...2 -29 999 ... 999 999 (100)
I/O extensions with CANopen
9499-040-82711
III-182
RM_DMS (strain gauge module (No. 22))