beautypg.com

Text 1 – West Control Solutions KS98-1 User Manual

Page 159

background image

*

Data type “digital”
Dependent digital input bit value of the relevant line, text "0" (Name_n) or text "1" (Unit_n) is displayed.
With a static input value, static text output can be generated (e.g. headline).

Example: value with limits:
In addition to its maximum number of digits behind the decimal point, each value can have its adjustment limits which
are determined by parameter values L1 and H1 of a connected ALLP block.
Unless the display value source is the VWERT itself, the ALLP limits the value with these parameter values.

Ö

Data type “time” (analog output)
Data type “time” can be used to display or to adjust ti-
mes in HH:MM:SS or HH:MM, whereby the last deci-
mal digit indicates the full minutes. The digits behind
the decimal point are for display of seconds.

w

With the digits behind the decimal point DP set to
0, adjustment of seconds is not possible. Only
hours and minutes can be adjusted. If the rele-
vant configuration value DP is 2, adjustment of
seconds is also possible.

w

From a time above 100 hours, seconds are not displayed any more.

w

The adjustment range is within 00:00:00 - 15999:59 hours. Due to the limited resolution of a float value, adjust -
ment ist possible only in steps of 6 seconds from value 16:40:00.

ä

Data type “radio” (radio button; digital output)
Data type ”radio button” can be used for changing over between combined selection fields.

w

After selecting, changing is done directly without starting with function key H .

w

“Radio button” arranged successively in one VWERT form a common group.

w

Only one element of this group is activated.

w

By actuating the function key, the radio button on which the cursor is standing is activated. All relevant other
ones are de-activated.

w

A new group starts, if another data type is defined between 2 radio buttons.

w

Unless a radio button is activated during data transmission to VWERT, all radio buttons remain inactive. If more
than 1 button is active, the 1st one of the group is activated, the other ones are inactive.

#

Data type “switch” (digital output)
Data type “switch” can be used to implement
switch-on/switch-off (toogle) functions.

w

After selection, adjusting is done directly without starting
with function key H.

w

Pressing the function key will activate a de-activated
switch and de-activate an activated switch.

<

Data type “push-button” (digital output)
Data type ”push-button” can be used to realize short
switch-on/switch-off (hold) functions.

w

After selection, adjusting is done directly without starting with function key H.

w

As long as the function key is pressed, the output is activated. When releasing the key, the output is de-acti -
vated.

Visualization

9499-040-82711

III-159

VWERT ( display / definition of process values (No. 96) )

ALLP

Y 1

h1

h2

l1

l2

X 1

115 ts=11

VWERT

Y 1
Y 2
Y 3
Y 4
Y 5
Y 6

Bl-no

Line

z1

z2

z3

z4

z5

z6

c

hange

X 1
X 2
X 3
X 4
X 5
X 6
Casc

hi

de

lo

c

k

d1

d2

d3

d4

d5

d6

st

o

re

116 ts=11

Fig. 20

Text 1

¤

£

|

Fig. 21