63

Table 19 – EAP-TLS/MSCHAPv2 Configuration Using .PFX or .P12 Private Key

Command

Description

wl-security tls

Sets the EAP authentication process to be used.

eap-ident [client username from
RADIUS server]

Sets the username/EAP Identity for the client.
There must be a valid username on the

RADIUS server that matches this name.
Replace the [client username from
RADIUS server]

with the user name (no

parenthesis).

ca-cert-filename [CA root cert
name].pem

Identifies the CA root certificate name to be
used. Replace [CA root cert name].pem
with the required filename (no parenthesis).

The certificate must be saved to the module
with the name identified by this command.

priv-key-password [client private
key password]

Sets the password for the client private key file
or Personal Information Exchange certificate.

This must be the password on the RADIUS
server that matches the key used to build the
private key file. Replace the [client
private key password]

with the password

for the private key file (no parenthesis).

priv-key-filename [client private
key name].[pem/pfx/p12]

Identifies he client private key file or Personal

Information Exchange certificate to be used.
Replace [client private key
name].[pem/pfx/p12]

with the required

filename (no parenthesis).

The private key file must be saved to the

module with the name identified by this
command.

When using .PFX/.P12 certificates with the module it is possible to authenticate to the
network without defining the CA Certificate. This is a non-preferred configuration and

is not recommended.

It is important to know that there are many variations and additional
configurations that the module supports. Please contact B&B Electronics
Technical Support if your configuration is not covered by the documentation.
There are additional parameters available; these are listed in section 19.0.