beautypg.com

Wl-tunnel-mode / wl-tunnel-mode-p1, Wl-tunnel-mode-p2 – B&B Electronics WLNN-AN(ER,SE,SP.EK)-DP551 - Manual User Manual

Page 244

background image

244

Airborne Enterprise CLI Reference Manual

wl-tunnel-mode / wl-tunnel-mode-p1

Command

wl-tunnel-mode | wl-tunnel-mode-p1

Arguments

tcp | udp | sds

Security

Level

Read: 3 (config)

Write: 4 (OEM)

Device Type Serial | UART | SPI

Default

tcp

Description

Configures the communication protocol that will be used by the tunnel port (wl-tunnel-port)
assigned to the Serial 1 (UART1) interface, for incoming communications.

Tcp

Sets TCP/IP as the protocol on the tunnel port.

Udp

Sets UDP as the protocol on the tunnel port.

Sds

Sets up SDS mode as the protocol for tunneling.

The data tunnel must be enabled (wl-tunnel 1) for communications to be successful.

Non-matching protocols attempting to connect to the tunnel port will be ignored.

The use of the –p1 suffix is optional.

wl-tunnel-mode-p2

Command

wl-tunnel-mode-p2

Arguments

tcp | udp | sds

Security
Level

Read: 3 (config)

Write: 4 (OEM)

Device Type Serial | UART | SPI

Default

tcp

Description

Configures the communication protocol that will be used by the tunnel port (wl-tunnel-port-p2)
assigned to the Serial 2 (UART2) interface, for incoming communications.

Tcp

Sets TCP/IP as the protocol on the tunnel port.

Udp

Sets UDP as the protocol on the tunnel port.

Sds

Sets up SDS mode as the protocol for tunneling.

The data tunnel must be enabled (wl-tunnel-p2 1) for communications to be successful.

Non-matching protocols attempting to connect to the tunnel port will be ignored.