Wl-udp-port / wl-udp-port-p1, Wl-udp-port-p2 – B&B Electronics WLNN-AN(ER,SE,SP.EK)-DP551 - Manual User Manual
Page 249

Airborne Enterprise CLI Reference Manual
249
wl-udp-port / wl-udp-port-p1
Command
wl-udp-port | wl-udp-port-p1
Arguments
Security
Level
3 (config)
Device Type Serial | UART | SPI
Default
8023
Description
Configures the UDP port number for the Serial 1 (UART1) interface to use when the CLI session on the
Serial 1 (UART1) interface initiates UDP transmissions. The port is used with the network server IP
address (wl-udp-ip) when the pass or serial-default pass commands are used.
For this setting to be used wl-xmit-type udp or wl-xmit-type both must be set.
The port number must match the port the target network UDP server is listening on.
The port range is 0 – 65535.
Use of the –p1 suffix is optional.
wl-udp-port-p2
Command
wl-udp-port-p2
Arguments
Security
Level
3 (config)
Device Type Serial | UART | SPI
Default
8024
Description
Configures the UDP port number for the Serial 2 (UART2) interface to use when the CLI session on the
Serial 2 (UART2) interface initiates UDP transmissions. The port is used with the network server IP
address (wl-udp-ip-p2) when the pass or serial-default pass commands are used.
For this setting to be used wl-xmit-type-p2 udp or wl-xmit-type-p2 both must be set.
The port number must match the port the target network UDP server is listening on.
The port range is 0 – 65535.