Airborne Enterprise CLI Reference Manual

timer-initial-delay

Command

timer-initial-delay

Arguments

[timer_number] [Integer]

Security

Level

3 (config)

Device Type All

Default

Integer/delay default is 0

Description

Specifies the delay in seconds between when timer [timer_number] is first enabled and when it first

triggers.

The range of [timer_number] is 1 - 8.

Range 0 to 31622400 (one year), default 0 (no initial delay).

timer-period

Command

timer-period

Arguments

[timer_number] [Integer]

Security
Level

3 (config)

Device Type All

Default

Integer/interval default is 0

Description

Specifies the interval in seconds between when timer [timer_number] completes its "timer-action" and
when it is next triggered.

The range of [timer_number] is 1 - 8.

Range 0 to 31622400 (one year), default 0 (one-shot: no re-trigger interval).