Wl-tcp-timeout / wl-tcp-timeout-p1, Wl-tcp-timeout-p2 – B&B Electronics WLNN-AN(ER,SE,SP.EK)-DP551 - Manual User Manual
Page 240

240
Airborne Enterprise CLI Reference Manual
wl-tcp-timeout / wl-tcp-timeout-p1
Command
wl-tcp-timeout | wl-tcp-timeout-p1
Arguments
Security
Level
3 (config)
Device Type Serial | UART | SPI
Default
0 (disabled)
Description
Configures the inactivity timeout for the Serial 1 (UART1) interface to use when the CLI session on the
Serial 1 (UART1) interface initiates a TCP connection. The timeout is applied when the pass or
serial-default pass
commands are used.
Data to or from the UART interface will cause the timeout to reset.
If the pass command was issued from the Serial 1 (UART1) interface and the timeout expires, the TCP
connection is terminated and the data tunnel broken. The Serial 1 (UART1) interface is returned to the
CLI command mode.
A value of zero (0) disables the timeout, creating an infinite timeout.
The range for the parameters is 0 – 4,294,967,295 seconds (32 bit binary unsigned).
Use of the –p1 suffix is optional.
wl-tcp-timeout-p2
Command
wl-tcp-timeout-p2
Arguments
Security
Level
3 (config)
Device Type Serial | UART | SPI
Default
0 (disabled)
Description
Configures the inactivity timeout for the Serial 2 (UART2) interface to use when the CLI session on the
Serial 2 (UART2) interface initiates a TCP connection. The timeout is applied when the pass or
serial-default-p2 pass
commands are used.
Data to or from the UART interface will cause the timeout to reset.
If the pass command was issued from the Serial 2 (UART2) interface and the timeout expires, the TCP
connection is terminated and the data tunnel broken. The Serial 2 (UART2) interface is returned to the
CLI command mode.
A value of zero (0) disables the timeout, creating an infinite timeout.
The range for the parameters is 0 – 4,294,967,295 seconds (32 bit binary unsigned).