Configuring a New Unit
www.lsi.com/channel/products
87
5
Tab to the
RAID Configuration
field and press
Enter
to see a list of
available configurations for the number of drives you selected.
Figure 45. Configuration Choices for Four Drives
6
Use the
arrow keys
to select the configuration you want and press
Enter
.
7
Tab
to the field
Stripe Size
and select the desired striping size (16, 64, or
256 KB).
Figure 46. Stripe Sizes for a RAID 5
8
(Optional)
Tab
through the policy fields and make any appropriate
changes to the default settings for:
•
Write Cache Setting
•
Read Cache Setting
•
StorSave Profile
•
Auto-Verify
•
Rapid RAID Recovery
For details about these settings, see “Configuration Options When
Creating a Unit” on page 79.
9
(Optional)
Tab
to the Advanced Options screen and make any appropriate
changes to the default settings for:
•
Boot Volume Size (in gigabytes)
•
Drive Queuing Mode
•
Continue on Error During Rebuild
•
Initialization method
For details about these settings, see “Configuration Options When
Creating a Unit” on page 79.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)