003f flash file system error detected, 0040 flash file system repaired – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 277

Error and Notification Messages
www.lsi.com/channel/products
265
003F Flash file system error detected
Event Type
Warning
Cause
A corrupted flash file system was found on the 3ware RAID controller during
boot-up.
The 3ware RAID controller stores configuration parameters as files in its
flash memory. These files can be corrupted when a flash operation is
interrupted by events such as a power failure. The controller will attempt to
restore the flash files from a backup copy.
Action
Update to the latest firmware, as earlier firmware resets corrupted files to
default settings.
We recommend using 3DM2, 3BM, or CLI to check your settings, in case
they were not able to be restored.
0040 Flash file system repaired
Event Type
Information
Cause
A corrupted flash file system has been successfully repaired.
Some of the flash files with insufficient data may have been lost in the
operation. The configuration parameters which are lost will then return to
their default values.
Action
We recommend using 3DM2, 3BM, or CLI to check your settings, in case
they were not able to be restored.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)