If the drive shows up, then you will know which hardware component
was defective.

If the drive still does not show up, contact 3ware Technical Support.

Error and Notification Messages

Error and notification messages are issued by the 3ware RAID controller
when an error is detected or when an action is completed. These messages are
sometimes referred to as AENs (asynchronous event notifications).

AEN messages are displayed on the 3DM2 Alarms page and CLI Show
Alarms page.

On the 3DM2 Alarms page, you can click on the message to jump to help text
about that message. You can also look the message up in the list below. In
3DM2, the message number is the last few digits within the parentheses at the
beginning of the message description. For example, in the string

(0x04:0x002B)

, “

002B

” is the message number. To find additional

information about the message 2B, you would look up 002B in the list below.

Note that the messages are listed below in hex order, since the message
numbers are in hex.

Error and notification messages are listed in Table 14. Descriptions of each
are provided after the table.

Table 14: Error and Notification Message List

Value Message

0001 Controller reset occurred

0002 Degraded unit

0003 Controller error occurred

0004 Rebuild failed

0005 Rebuild completed

0006 Incomplete unit detected

0007 Initialize completed

0008 Unclean shutdown detected

0009 Drive timeout detected