0057 battery charging fault, 0058 battery capacity is below warning level – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 286
Chapter 12. Troubleshooting
274
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
0057 Battery charging fault
Event Type
Error
Cause
The Battery Backup Unit has detected a battery fault during a charge cycle.
The Battery Backup Unit is not ready and is unable to backup the 3ware
RAID controller.
Action
Replace the battery pack.
See Also
See the Install Guide for your controller
0058 Battery capacity is below warning level
Event Type
Information
Cause
The measured capacity of the battery is below the warning level. The Battery
Backup Unit is presently still able to backup the 3ware RAID controller, but it
is weakening.
Action
Replace the battery pack if the warnings persist.
See Also
See the Install Guide for your controller.
This manual is related to the following products:
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)