Specifying a hot spare – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 38
Chapter 2. First-Time RAID Configuration Using 3BM
26
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Specifying a Hot Spare
You can designate one of the Available Drives as a hot spare in 3BM. If a hot
spare is specified and a redundant unit degrades, an event notification is
generated. If the hot spare is of the same type (SAS or SATA) and of adequate
size, the hot spare automatically replaces the failed drive without user
intervention.
To specify a hot spare
1
In the list of Available Drives, highlight the drive to use.
2
Type s to specify that the selected drive will be the hot spare.
The words “Hot Spare” appear next to the drive in the Available Drives
list.
Figure 17. Hot Spare Indicated
If a hot spare is already enabled, you can disable it by following the same
process.
(Patrick_1)
(Patrick_2)
Note:
To replace a failed drive in a degraded unit, make sure that a hot spare
drive has the same or larger storage capacity than the failed drive.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)