Maintenance page
www.lsi.com/channel/products
215
Figure 105. Configuration Window in 3DM2
For more detailed instructions, see “Configuring a New Unit” on page 79.
Type.
The drop-down list lists the possible RAID configurations for the drives
selected in the list of Available Drives. Available configurations may include
RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, and Single Disk. For
information about these configurations, see “Available RAID Configurations”
on page 6.
Depending on the size of the unit, a RAID 50 unit will contain 2 or more
subunits. For example, when you are configuring a RAID 50 with twelve
drives, an additional field appears, in which you select the number of drives
per subunit—3, 4, or 6.
Figure 106. Configuring a RAID 50 with 12 Drives
Name.
You can enter a name for the unit.
Stripe.
The drop-down list of stripe sizes lists the possible stripe sizes for the
configuration you selected in the RAID level drop-down.
Using the default stripe size of 256 KB usually gives you the best
performance for mixed I/Os. If your application has some specific I/O pattern
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)